Standard Power Conditioners and Power Protection
Thanks to their low-impedance isolation transformer, you can
trust these power conditioners to protect your sensitive equipment from
the biggest problem for today’s computers: common-mode voltage, which
can cause everything from equipment lock-ups to data losses and more.
All North American models have UL and cUL listings. International Models
are safety agency listed and carry the CE mark.
These models also feature surge diverters and power line filters to
eliminate noise, spikes and transients before they have a chance to
damage your equipment.
|
|
Suitable for use with instrumentation, analyzers, desktop PCs, LANs, communications systems and telephone systems |
|
|
Prevents hardware destruction, component degradation, and operational disruption |
|
|
Red flashing LED(amber for international models) warns if the AC outlet is missing its input safety ground |
|
|
Let-through voltage is <10 volts normal mode and < .5 volts neutral to ground when tested to ANSI/IEEE C62.41 |
|
|
POWERVAR`s five-year warranty on parts and labor provides complete peace of mind |
Optional Rackmount assembly available for models ABC400-11 to ABC700-11.
Wall mount kits are also available.
Ground Guard Conditioners
Ground Guard power conditioners provide networked systems with
benefits beyond those of traditional power conditioning products. Filter
elements in the safety ground circuit prevent the formation of “ground
loops,” which are common in networked applications.
This “ground conditioning” feature combined with a high energy surge
diverter and a power line filter completely eliminates the need for both
dedicated electrical circuits and isolated ground wiring.
|
|
Ground Guard conditioning circuitry eliminates ground loops |
|
|
Red LED (amber for international models) flashes if AC outlet is missing its input safety ground |
|
|
Prevents hardware destruction, component degradation, and operational disruption |
|
|
Let-through voltage is <10 volts normal mode and < .5 volts neutral to ground when tested to ANSI/IEEE C62.41 |
|
|
All models are safety agency listed. International models carry the CE mark |
|
|
POWERVAR`s five-year warranty on parts and labor provides complete peace of mind |
Optional Rackmount assembly available.
Single Phase Power Conditioners
If you have a small or mid-range computer system, multiple
network servers, a large phone or voice-mail system, or other critical
equipment that requires more power, POWERVAR single-phase conditioners
can save you time and frustration. All are UL and cUL listed.
Whether noise is generated on the line or by the load, this equipment`s
low-impedance transformer and bi-directional noise filter protects your
system from all the problems caused by power disturbances, from lost
data to "no trouble found" service calls and more.
|
|
Conditioners provide clean power at 120, 208 or 240 VAC for loads up to 62 amps |
|
|
Dual-output
models can protect both high-voltage system loads and low-voltage
peripherals at less expense and effort than installing two conditioners |
|
|
Hardwired and line cord/receptacle models are available |
|
|
All models include POWERVAR`s five-year warranty on parts and labor |